DC GEAR MOTOR
Return
Product details
GENERAL SPECIFICATION OF MOTORS |
|
TYPE: 1W-180W | |
Item | Specification |
Insulation Resistance | In the circumstance of normal ambient temperature and humidity, the resistance can be up to |
100MΩ or more When 500VDC megger is applied betw een the w inding and the frame after rated motor operations. | |
Dielectric Strength | In the circumstance of normal ambient temperature and humidity, there w ill be no problem to |
w ithstand 1.5 kV(three phase 400V:2kV) at 50/60Hz betw een the w indings and the frame | |
for 1 minute after rated motor operation. | |
Temperature Rise | Temperature rise of w indings are 80°C or less measured by the resistance change method after |
rated motor Operation w ith connecting a gearhead or equivalent heat radiation plated. | |
(Three-phase type: 70°C or less ) | |
Insulation Class | UL/CSA Standards: Class A (105°C) EN Standards: Class B (105°C) Class F (155°C) |
Overheat Protection | Thermal Protector inside (automatic returm) |
Class B (opening; 120°C±5°C, 75°C±15°C) | |
Class F (opening; 145°C±5°C, 100°C±15°C) | |
Ambient Temperature | Single-Phase 100VAC, Three-Phase 200VAC: -10~+ 50°C(Nonfreezing) |
Others: -10~ + 40°C (Nonfreezing) | |
Ambient Humidity | 85% or less (Noncondensing) |
Degree of Protection | Lead Wire Type: IP20 |
Terminal Box Type | |
Single-phase 100V50/60Hz, 110/120V60Hz, 220/230V50Hz, 220/230V60Hz | |
25W-180W Type: IP54 (Excluing the installation surface of the round shaft type ) | |
Three-phase 200/220/230V//50/60Hz, 380/400/415V//50/60Hz | |
25W-180W Type: IP54 ( Excluing the installation surface of the round shaft type ) |