Automatic Drive Equipment
DC GEAR MOTOR
Return
Product details

 

 

GENERAL SPECIFICATION OF MOTORS

TYPE: 1W-180W
Item Specification
Insulation Resistance In the circumstance of normal ambient temperature and humidity, the resistance can be up to
100MΩ or more When 500VDC megger is applied betw een the w inding and the frame after rated motor operations.
Dielectric Strength In the circumstance of normal ambient temperature and humidity, there w ill be no problem to
w ithstand 1.5 kV(three phase 400V:2kV) at 50/60Hz betw een the w indings and the frame
for 1 minute after rated motor operation.
Temperature Rise Temperature rise of w indings are 80°C or less measured by the resistance change method after
rated motor Operation w ith connecting a gearhead or equivalent heat radiation plated.
(Three-phase type: 70°C or less )
Insulation Class UL/CSA Standards: Class A (105°C) EN Standards: Class B (105°C) Class F (155°C)
Overheat Protection Thermal Protector inside (automatic returm)
Class B (opening; 120°C±5°C, 75°C±15°C)
Class F (opening; 145°C±5°C, 100°C±15°C)
Ambient Temperature Single-Phase 100VAC, Three-Phase 200VAC: -10~+ 50°C(Nonfreezing)
Others: -10~ + 40°C (Nonfreezing)
Ambient Humidity 85% or less (Noncondensing)
Degree of Protection Lead Wire Type: IP20
Terminal Box Type
Single-phase 100V50/60Hz, 110/120V60Hz, 220/230V50Hz, 220/230V60Hz
25W-180W Type: IP54 (Excluing the installation surface of the round shaft type )
Three-phase 200/220/230V//50/60Hz, 380/400/415V//50/60Hz
25W-180W Type: IP54 ( Excluing the installation surface of the round shaft type )

 

 
Return